Single Conductor 600V Secondary Type URD Cable Aluminum Conductor Ruggedized
Single Conductor Type URD Cable - Aluminum Conductor
Item # |
Phase
|
Phase
|
Phase
|
Diameter
|
Diameter
|
Weight
|
Allowable
|
Allowable
|
---|---|---|---|---|---|---|---|---|
Princeton/R |
Phase Conductor Size/AWG N/A 6 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Insulation Thickness (mils) N/A 60 |
Diameter Bare Conductor (mils) N/A 178 |
Diameter Complete Cable (mils) N/A 298 |
Weight (lb/1000 ft) N/A 44 |
Allowable Ampacities+ Direct Burial N/A 90 |
Allowable Ampacities+ In Duct N/A 65 |
Rutgers/R |
Phase Conductor Size/AWG N/A 350 |
Phase Conductor Stranding N/A 37 |
Phase Conductor Insulation Thickness (mils) N/A 95 |
Diameter Bare Conductor (mils) N/A 641 |
Diameter Complete Cable (mils) N/A 831 |
Weight (lb/1000 ft) N/A 423 |
Allowable Ampacities+ Direct Burial N/A 385 |
Allowable Ampacities+ In Duct N/A 305 |
Gonzaga/R |
Phase Conductor Size/AWG N/A 300 |
Phase Conductor Stranding N/A 37 |
Phase Conductor Insulation Thickness (mils) N/A 95 |
Diameter Bare Conductor (mils) N/A 594 |
Diameter Complete Cable (mils) N/A 784 |
Weight (lb/1000 ft) N/A 370 |
Allowable Ampacities+ Direct Burial N/A 355 |
Allowable Ampacities+ In Duct N/A 280 |
Beloit/R |
Phase Conductor Size/AWG N/A 4/0 |
Phase Conductor Stranding N/A 18 |
Phase Conductor Insulation Thickness (mils) N/A 80 |
Diameter Bare Conductor (mils) N/A 498 |
Diameter Complete Cable (mils) N/A 658 |
Weight (lb/1000 ft) N/A 264 |
Allowable Ampacities+ Direct Burial N/A 290 |
Allowable Ampacities+ In Duct N/A 225 |
Tufts/R |
Phase Conductor Size/AWG N/A 3/0 |
Phase Conductor Stranding N/A 17 |
Phase Conductor Insulation Thickness (mils) N/A 80 |
Diameter Bare Conductor (mils) N/A 443 |
Diameter Complete Cable (mils) N/A 603 |
Weight (lb/1000 ft) N/A 216 |
Allowable Ampacities+ Direct Burial N/A 250 |
Allowable Ampacities+ In Duct N/A 195 |
Yale/R |
Phase Conductor Size/AWG N/A 2/0 |
Phase Conductor Stranding N/A 11 |
Phase Conductor Insulation Thickness (mils) N/A 80 |
Diameter Bare Conductor (mils) N/A 395 |
Diameter Complete Cable (mils) N/A 555 |
Weight (lb/1000 ft) N/A 177 |
Allowable Ampacities+ Direct Burial N/A 225 |
Allowable Ampacities+ In Duct N/A 170 |
Harvard/R |
Phase Conductor Size/AWG N/A 1/0 |
Phase Conductor Stranding N/A 9 |
Phase Conductor Insulation Thickness (mils) N/A 80 |
Diameter Bare Conductor (mils) N/A 352 |
Diameter Complete Cable (mils) N/A 512 |
Weight (lb/1000 ft) N/A 146 |
Allowable Ampacities+ Direct Burial N/A 200 |
Allowable Ampacities+ In Duct N/A 150 |
Kenyon/R |
Phase Conductor Size/AWG N/A 1 |
Phase Conductor Stranding N/A 9 |
Phase Conductor Insulation Thickness (mils) N/A 80 |
Diameter Bare Conductor (mils) N/A 313 |
Diameter Complete Cable (mils) N/A 473 |
Weight (lb/1000 ft) N/A 121 |
Allowable Ampacities+ Direct Burial N/A 175 |
Allowable Ampacities+ In Duct N/A 130 |
Clemson/R |
Phase Conductor Size/AWG N/A 2 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Insulation Thickness (mils) N/A 60 |
Diameter Bare Conductor (mils) N/A 283 |
Diameter Complete Cable (mils) N/A 403 |
Weight (lb/1000 ft) N/A 92 |
Allowable Ampacities+ Direct Burial N/A 155 |
Allowable Ampacities+ In Duct N/A 115 |
Mercer/R |
Phase Conductor Size/AWG N/A 4 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Insulation Thickness (mils) N/A 60 |
Diameter Bare Conductor (mils) N/A 225 |
Diameter Complete Cable (mils) N/A 345 |
Weight (lb/1000 ft) N/A 63 |
Allowable Ampacities+ Direct Burial N/A 120 |
Allowable Ampacities+ In Duct N/A 85 |