Applications
AA-8000 SER is Type SE, Style R cable, used as an above ground service entrance cable, a panel feeder and in branch circuits. The cable is rated at 600 volts and 90ºC for use in wet and dry locations in accordance with NEC Article 338.
Construction
Conductor: Compact stranded AA-8000 series aluminum conductor material per ASTM B800, ASTM B801, ASTM B836, ASTM B901 (Single Input Wire), as applicable.
Insulation: Color coded cross-linked polyethylene (XLPE).
Assembly: Insulated conductors are cabled with the bare ground wire. A flame retardant fiberglass reinforced binder tape assembles the core in a circular configuration.
Jacket: Sunlight resistant, RoHS compliant, flame retardant, gray polyvinyl chloride (PVC) material.
Conductor Identification:
3 Conductor Color coded: Black, White and Red
4 Conductor Color coded: Black, White, Red and Blue
Surface Print Legend: [manufacturer] 8000 TYPE SE - STYLE: R 600V XHHW AA-8000-AL [SIZE] AWG (UL) E-xxxxxx SUN RES ROHS (MFG. DATE) (SEQUENTIAL MARKING IN FEET)
Standards
- UL 44
- UL 854: Service Entrance Cables
- Federal specification JC-30B NEC
- RoHS compliant
Packaging
- 250 ft reels
- 500 ft reels
- 1000 ft reels
- Master reels
- Coils
Ampacity
To determine correct ampacity by conductor size, please consult the National Electric Code, Latest edition.
Item # |
Number
|
Bare
|
Nominal
|
Approximate
|
Amps
|
Ampacity
|
---|---|---|---|---|---|---|
A8-02SER8 A8-02SER8/Asset/ser.jpg |
Number of Conductors N/A 2 |
Bare Ground Conductor Size N/A 8 |
Nominal O.D. N/A 0.49 |
Approximate Weight lbs/MFT N/A 97 |
Amps 90ºC N/A 45 |
Ampacity In Dwelling 90ºC (amps) N/A N/A |
A6-02SER6 A6-02SER6/Asset/ser.jpg |
Number of Conductors N/A 2 |
Bare Ground Conductor Size N/A 6 |
Nominal O.D. N/A 0.57 |
Approximate Weight lbs/MFT N/A 138 |
Amps 90ºC N/A 60 |
Ampacity In Dwelling 90ºC (amps) N/A N/A |
A4-02SER6 A4-02SER6/Asset/ser.jpg |
Number of Conductors N/A 2 |
Bare Ground Conductor Size N/A 6 |
Nominal O.D. N/A 0.63 |
Approximate Weight lbs/MFT N/A 177 |
Amps 90ºC N/A 75 |
Ampacity In Dwelling 90ºC (amps) N/A N/A |
A4-02SER4 A4-02SER4/Asset/ser.jpg |
Number of Conductors N/A 2 |
Bare Ground Conductor Size N/A 4 |
Nominal O.D. N/A 0.67 |
Approximate Weight lbs/MFT N/A 193 |
Amps 90ºC N/A 75 |
Ampacity In Dwelling 90ºC (amps) N/A N/A |
A2-02SER4 A2-02SER4/Asset/ser.jpg |
Number of Conductors N/A 2 |
Bare Ground Conductor Size N/A 4 |
Nominal O.D. N/A 0.75 |
Approximate Weight lbs/MFT N/A 254 |
Amps 90ºC N/A 100 |
Ampacity In Dwelling 90ºC (amps) N/A 100 |
A2-02SER2 A2-02SER2/Asset/ser.jpg |
Number of Conductors N/A 2 |
Bare Ground Conductor Size N/A 2 |
Nominal O.D. N/A 0.79 |
Approximate Weight lbs/MFT N/A 280 |
Amps 90ºC N/A 100 |
Ampacity In Dwelling 90ºC (amps) N/A 100 |
A1-02SER1 A1-02SER1/Asset/ser.jpg |
Number of Conductors N/A 2 |
Bare Ground Conductor Size N/A 1 |
Nominal O.D. N/A 0.88 |
Approximate Weight lbs/MFT N/A 349 |
Amps 90ºC N/A 115 |
Ampacity In Dwelling 90ºC (amps) N/A 110 |
A1/0-02SER2 A1/0-02SER2/Asset/ser.jpg |
Number of Conductors N/A 2 |
Bare Ground Conductor Size N/A 2 |
Nominal O.D. N/A 0.92 |
Approximate Weight lbs/MFT N/A 384 |
Amps 90ºC N/A 135 |
Ampacity In Dwelling 90ºC (amps) N/A 125 |
A1/0-02SER1/0 A1/0-02SER1/0/Asset/ser.jpg |
Number of Conductors N/A 2 |
Bare Ground Conductor Size N/A 1/0 |
Nominal O.D. N/A 0.96 |
Approximate Weight lbs/MFT N/A 423 |
Amps 90ºC N/A 135 |
Ampacity In Dwelling 90ºC (amps) N/A 125 |
A2/0-02SER1 A2/0-02SER1/Asset/ser.jpg |
Number of Conductors N/A 2 |
Bare Ground Conductor Size N/A 1 |
Nominal O.D. N/A 0.95 |
Approximate Weight lbs/MFT N/A 459 |
Amps 90ºC N/A 150 |
Ampacity In Dwelling 90ºC (amps) N/A 150 |
A2/0-02SER2/0 A2/0-02SER2/0/Asset/ser.jpg |
Number of Conductors N/A 2 |
Bare Ground Conductor Size N/A 2/0 |
Nominal O.D. N/A 1.05 |
Approximate Weight lbs/MFT N/A 513 |
Amps 90ºC N/A 150 |
Ampacity In Dwelling 90ºC (amps) N/A 150 |
A4/0-02SER2/0 A4/0-02SER2/0/Asset/ser.jpg |
Number of Conductors N/A 2 |
Bare Ground Conductor Size N/A 2/0 |
Nominal O.D. N/A 1.19 |
Approximate Weight lbs/MFT N/A 690 |
Amps 90ºC N/A 205 |
Ampacity In Dwelling 90ºC (amps) N/A 200 |
A4/0-02SER4/0 A4/0-02SER4/0/Asset/ser.jpg |
Number of Conductors N/A 2 |
Bare Ground Conductor Size N/A 4/0 |
Nominal O.D. N/A 1.26 |
Approximate Weight lbs/MFT N/A 766 |
Amps 90ºC N/A 205 |
Ampacity In Dwelling 90ºC (amps) N/A 200 |
A8-03SER8 A8-03SER8/Asset/ser.jpg |
Number of Conductors N/A 3 |
Bare Ground Conductor Size N/A 8 |
Nominal O.D. N/A 0.57 |
Approximate Weight lbs/MFT N/A 128 |
Amps 90ºC N/A 45 |
Ampacity In Dwelling 90ºC (amps) N/A N/A |
A6-03SER6 A6-03SER6/Asset/ser.jpg |
Number of Conductors N/A 3 |
Bare Ground Conductor Size N/A 6 |
Nominal O.D. N/A 0.65 |
Approximate Weight lbs/MFT N/A 182 |
Amps 90ºC N/A 60 |
Ampacity In Dwelling 90ºC (amps) N/A N/A |
A4-03SER6 A4-03SER6/Asset/ser.jpg |
Number of Conductors N/A 3 |
Bare Ground Conductor Size N/A 6 |
Nominal O.D. N/A 0.74 |
Approximate Weight lbs/MFT N/A 240 |
Amps 90ºC N/A 75 |
Ampacity In Dwelling 90ºC (amps) N/A N/A |
A2-03SER4 A2-03SER4/Asset/ser.jpg |
Number of Conductors N/A 3 |
Bare Ground Conductor Size N/A 4 |
Nominal O.D. N/A 0.86 |
Approximate Weight lbs/MFT N/A 346 |
Amps 90ºC N/A 100 |
Ampacity In Dwelling 90ºC (amps) N/A 100 |
A1-03SER3 A1-03SER3/Asset/ser.jpg |
Number of Conductors N/A 3 |
Bare Ground Conductor Size N/A 3 |
Nominal O.D. N/A 0.97 |
Approximate Weight lbs/MFT N/A 435 |
Amps 90ºC N/A 115 |
Ampacity In Dwelling 90ºC (amps) N/A 110 |
A1/0-03SER2 A1/0-03SER2/Asset/ser.jpg |
Number of Conductors N/A 3 |
Bare Ground Conductor Size N/A 2 |
Nominal O.D. N/A 1.06 |
Approximate Weight lbs/MFT N/A 526 |
Amps 90ºC N/A 135 |
Ampacity In Dwelling 90ºC (amps) N/A 125 |
A2/0-03SER1 A2/0-03SER1/Asset/ser.jpg |
Number of Conductors N/A 3 |
Bare Ground Conductor Size N/A 1 |
Nominal O.D. N/A 1.16 |
Approximate Weight lbs/MFT N/A 637 |
Amps 90ºC N/A 150 |
Ampacity In Dwelling 90ºC (amps) N/A 150 |
A3/0-03SER1/0 A3/0-03SER1/0/Asset/ser.jpg |
Number of Conductors N/A 3 |
Bare Ground Conductor Size N/A 1/0 |
Nominal O.D. N/A 1.27 |
Approximate Weight lbs/MFT N/A 776 |
Amps 90ºC N/A 175 |
Ampacity In Dwelling 90ºC (amps) N/A 175 |
A4/0-03SER2/0 A4/0-03SER2/0/Asset/ser.jpg |
Number of Conductors N/A 3 |
Bare Ground Conductor Size N/A 2/0 |
Nominal O.D. N/A 1.39 |
Approximate Weight lbs/MFT N/A 948 |
Amps 90ºC N/A 205 |
Ampacity In Dwelling 90ºC (amps) N/A 200 |
A250-03SER3/0 A250-03SER3/0/Asset/ser.jpg |
Number of Conductors N/A 3 |
Bare Ground Conductor Size N/A 3/0 |
Nominal O.D. N/A 1.60 |
Approximate Weight lbs/MFT N/A 1106 |
Amps 90ºC N/A 230 |
Ampacity In Dwelling 90ºC (amps) N/A 225 |
A300-03SER4/0 A300-03SER4/0/Asset/ser.jpg |
Number of Conductors N/A 3 |
Bare Ground Conductor Size N/A 4/0 |
Nominal O.D. N/A 1.74 |
Approximate Weight lbs/MFT N/A 1311 |
Amps 90ºC N/A 255 |
Ampacity In Dwelling 90ºC (amps) N/A 250 |
A2-04SER4 A2-04SER4/Asset/ser.jpg |
Number of Conductors N/A 4 |
Bare Ground Conductor Size N/A 4 |
Nominal O.D. N/A 0.97 |
Approximate Weight lbs/MFT N/A 438 |
Amps 90ºC N/A 100 |
Ampacity In Dwelling 90ºC (amps) N/A 100 |
A2/0-04SER1 A2/0-04SER1/Asset/ser.jpg |
Number of Conductors N/A 4 |
Bare Ground Conductor Size N/A 1 |
Nominal O.D. N/A 1.30 |
Approximate Weight lbs/MFT N/A 807 |
Amps 90ºC N/A 150 |
Ampacity In Dwelling 90ºC (amps) N/A 150 |
A4/0-04SER2/0 A4/0-04SER2/0/Asset/ser.jpg |
Number of Conductors N/A 4 |
Bare Ground Conductor Size N/A 2/0 |
Nominal O.D. N/A 1.56 |
Approximate Weight lbs/MFT N/A 1204 |
Amps 90ºC N/A 205 |
Ampacity In Dwelling 90ºC (amps) N/A 200 |
A250-04SER3/0 A250-04SER3/0/Asset/ser.jpg |
Number of Conductors N/A 4 |
Bare Ground Conductor Size N/A 3/0 |
Nominal O.D. N/A 1.80 |
Approximate Weight lbs/MFT N/A 1404 |
Amps 90ºC N/A 230 |
Ampacity In Dwelling 90ºC (amps) N/A 225 |